| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 | 1 | 绝缘层的标称厚度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.2.2 表2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | ||
| 2 | 2 | 挤包半导电层最薄点厚度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.3.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 3 | 3 | 绕包用半导电带体积电阻率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.3.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 4 | 4 | 绝缘屏蔽最薄点厚度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.3.3 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 5 | 5 | 屏蔽铜丝的标称直径 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.5.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 6 | 6 | 相邻屏蔽铜丝的平均间隙G | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.5.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 7 | 7 | 铝套用铝或铝合金纯度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.6.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 8 | 8 | 焊接用铝带的断裂伸长率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.6.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 9 | 9 | 金属套的标称厚度 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.6.2 表3 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 10 | 10 | 非金属外护套的标称厚度 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.7.2 表4 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 11 | 11 | 挤塑半导电层厚度占外护套标称厚度的比例 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 6.7.3 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 12 | 12 | 局部放电试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表6 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第9.2条 | |||
| 13 | 13 | 电压试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表6 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第9.3条 | |||
| 14 | 14 | 非金属外护套的电气试验 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表6 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第9.4条 | |||
| 15 | 15 | 导体检验 | 040503 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.4条 | |||
| 16 | 16 | 导体和金属屏蔽电阻测量 | 040503 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.5条 | |||
| 17 | 17 | 绝缘厚度测量 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.6.2条 | |||
| 18 | 18 | 铜丝屏蔽的检查(适用时) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 19 | 19 | 金属套厚度测量 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.7条 | |||
| 20 | 20 | 非金属外护套厚度测量 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.6.3条 | |||
| 21 | 21 | 直径测量(要求时进行) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.8条 | |||
| 22 | 22 | 绝缘热延伸试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7、表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.9条 | |||
| 23 | 23 | 电容测量 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.10条 | |||
| 24 | 24 | 雷电冲击电压试验(适用时) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.11条 | |||
| 25 | 25 | 透水试验(适用时) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.12条 | |||
| 26 | 26 | 具有与外护套黏结的纵包金属带或纵包金属箔电缆组件的试验(适用时) | 040501 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第10.13条 | |||
| 27 | 27 | 绝缘厚度检验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.1条 | |||
| 28 | 28 | 弯曲试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.3条 | |||
| 29 | 29 | 室温下的局部放电试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.4条 | |||
| 30 | 30 | tanδ测量 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.5条 | |||
| 31 | 31 | 热循环电压试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.6条 | |||
| 32 | 32 | 局部放电试验(最后一次热循环后或雷电冲击电压试验后进行)-高温下 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.4条 | |||
| 33 | 33 | 局部放电试验(最后一次热循环后或雷电冲击电压试验后进行)-室温下 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.4条 | |||
| 34 | 34 | 雷电冲击电压试验及随后的工频电压试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.7条 | |||
| 35 | 35 | 局部放电试验(如上述局部放电试验没有进行)-高温下 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.4条 | |||
| 36 | 36 | 局部放电试验(如上述局部放电试验没有进行)-室温下 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.4条 | |||
| 37 | 37 | 检验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.8条 | |||
| 38 | 38 | 半导电屏蔽电阻率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.4.9条 | |||
| 39 | 39 | 电缆结构检查 | 040501 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.2条 | |||
| 40 | 40 | 绝缘老化前后机械性能试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.3条 | |||
| 41 | 41 | 非金属外护套老化前后机械性能试验 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.4条 | |||
| 42 | 42 | 成品电缆段相容性老化试验 | 040501 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.5条 | |||
| 43 | 43 | PVC外护套失重试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.6条 | |||
| 44 | 44 | 外护套高温压力试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.7条 | |||
| 45 | 45 | 外护套低温试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.8条 | |||
| 46 | 46 | PVC外护套热冲击试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.9条 | |||
| 47 | 47 | 绝缘微孔杂质试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.10条 | |||
| 48 | 48 | 半导电屏蔽层与绝缘层界面的微孔与突起试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.12条 | |||
| 49 | 49 | 黑色PE外护套炭黑含量测量(仅适用于非阻燃护套) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.13条 | |||
| 50 | 50 | 燃烧试验(要求时进行) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.14条 | |||
| 51 | 51 | 纵向透水试验(要求时进行) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.15条 | |||
| 52 | 52 | 具有与外护套黏结的纵包金属带或纵包金属箔电缆的组件试验 | 040501 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.16条 | |||
| 53 | 53 | XLPE绝缘收缩试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.17条 | |||
| 54 | 54 | 外护套收缩试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.18条 | |||
| 55 | 55 | 非金属外护套刮磨试验 | 040509 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.19条 | |||
| 56 | 56 | 铝套腐蚀扩展试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.20条 | |||
| 57 | 57 | 外护套吸水试验 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables 引用方法:GB/T 11017.1—2024 第12.5.21条 | |||
| 58 | 58 | 成品电缆标志的检查 | 040501 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表8 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 59 | 59 | 抗张强度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 60 | 60 | 断裂伸长率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 61 | 61 | 热延伸试验负荷下伸长率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 62 | 62 | 热延伸试验永久变形率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 63 | 63 | 介电常数 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 64 | 64 | 介质损失角正切tanδ | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 65 | 65 | 短时工频击穿强度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 66 | 66 | 体积电阻率(23℃) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 67 | 67 | 体积电阻率(90℃) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 68 | 68 | 杂质最大尺寸(1 kg样片中) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 69 | 69 | 纵向断裂伸长率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 70 | 70 | 含水率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 71 | 71 | pH | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 72 | 72 | 表面电阻 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 73 | 73 | 体积电阻率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 74 | 74 | 膨胀高度(热稳定性230°C×20s) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 75 | 75 | 表面电阻(热稳定性230°C×20s) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 76 | 76 | 体积电阻率(热稳定性230°C×20s) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 77 | 77 | 表面电阻(热老化135°C×168h) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 78 | 78 | 体积电阻率(热老化135°C×168h) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||
| 79 | 79 | pH(热老化135°C×168h) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 2 部分:电缆》GB/T11017.2-2024 表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um = 72.5 kV) and 110 kV (Um = 126 kV) —Part 2: Power cables | |||