| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 | 1 | 统一爬电比距 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 5.1.5 表1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | ||
| 2 | 2 | 三相系统爬电比距 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 5.1.5 表1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 3 | 3 | SF6气体设计压力(20℃,相对压力) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 4.3 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 4 | 4 | SF6气体最低功能压力(相对压力) | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 4.3 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 5 | 5 | 抗张强度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表A.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 6 | 6 | 断裂伸长率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表A.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 7 | 7 | 抗张强度最大变化率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表A.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 8 | 8 | 断裂伸长率最大变化率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表A.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 9 | 9 | 体积电阻率 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表A.1、表B.1、表C.1 等4处 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 10 | 10 | tanδ | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 11 | 11 | 介电常数 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 12 | 12 | 短时工频击穿电场强度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 13 | 13 | 热变形温度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 14 | 14 | 外观 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1、表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 15 | 15 | 运动黏度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 16 | 16 | 闪点 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1、表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 17 | 17 | 折光指数 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1、表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 18 | 18 | 击穿电压 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1、表C.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||
| 19 | 19 | 挥发度 | 040599 | 《额定电压 66 kV(Um=72.5 kV)和 110 kV(Um=126 kV)交联聚乙烯绝缘电力电缆及其附件 第 3 部分: 电缆附件》GB/T11017.3-2024 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um=126 kV)—Part 3: Accessories | |||