| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 矿用橡套软电缆 | 1 | 动力线芯20℃时绝缘电阻 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 7.1 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 3048.5—2007《》 | ||
| 2 | 2 | 控制线芯20℃时绝缘电阻 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 7.1 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 3048.5—2007《》 | |||
| 3 | 3 | 绝缘屏蔽过渡电阻 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 7.2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 4 | 4 | 工频交流电压试验 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 7.3 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 3048.8—2007《》 | |||
| 5 | 5 | 燃烧试验 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 7.4 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 18380.1—2001《》 | |||
| 6 | 6 | 加强层覆盖密度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 6.5 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 7 | 7 | 线芯绞合节径比 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 6.4 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 8 | 8 | 动力线芯绝缘标称厚度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 2951.11—2008《》 | |||
| 9 | 9 | 内护套计算厚度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 2951.11—2008《》 | |||
| 10 | 10 | 外护套标称厚度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 2951.11—2008《》 | |||
| 11 | 11 | 电缆外径 | 040501 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV 引用方法:GB/T 2951.11—2008《》 | |||
| 12 | 12 | 抗张强度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号1.1、表B.1 序号1.1 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 13 | 13 | 断裂伸长率 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号1.2、表B.1 序号1.2、2.2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 14 | 14 | 抗张强度变化率 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号2.1、3.1、表B.1 序号2.1、4.1 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 15 | 15 | 断裂伸长率变化率 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号2.2、3.2、表B.1 序号2.3、4.2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 16 | 16 | 体积电阻率 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号4 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 17 | 17 | 载荷伸长率 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号5.1、表B.1 序号5.1 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 18 | 18 | 冷却后永久变形 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表A.1 序号5.2、表B.1 序号5.2 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 19 | 19 | 抗撕强度 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表B.1 序号3 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||
| 20 | 20 | 表面电阻系数 | 040599 | 《矿用橡套软电缆 第 3 部分: 额定电压 0.66/1.14 kV 采煤机屏蔽监视加强型软电缆》GB/T12972.3-2008 表B.1 序号6 Flexible rubber-sheathed cables for mining purposes—Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV | |||