| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 高压直流输电系统用并联电容器及交流滤波电容器 | 1 | 电容偏差(并联电容器单元) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.4.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | |||
| 2 | 2 | 电容偏差(交流滤波电容器单元) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.4.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 3 | 3 | 电容偏差(并联电容器组) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.4.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 4 | 4 | 电容偏差(交流滤波电容器组) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.4.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 5 | 5 | 电容器组各串联段最大与最小电容之比 | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.4.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 6 | 6 | 绝缘电阻 | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.20 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 7 | 7 | 套管水平拉力(200kvar以下) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 8 | 8 | 套管水平拉力(200kvar以上) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 9 | 9 | 导电杆扭矩(M10) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 10 | 10 | 导电杆扭矩(M12) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 11 | 11 | 导电杆扭矩(M16) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 12 | 12 | 导电杆扭矩(M20) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.19 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 13 | 13 | 内部最热点温度 | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.23 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 14 | 14 | 局部放电熄灭电压(下限温度) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.25 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 15 | 15 | 外壳耐爆能量(全膜电容器) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.26 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 16 | 16 | 水平加速度(抗震) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.27 Shunt capacitors and AC filter capacitors for HVDC transmission systems 引用方法:GB/T 13540 | ||||
| 17 | 17 | 垂直加速度(抗震) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.27 Shunt capacitors and AC filter capacitors for HVDC transmission systems 引用方法:GB/T 13540 | ||||
| 18 | 18 | 热稳定性试验环境空气温度(代号A) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.12.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 19 | 19 | 热稳定性试验环境空气温度(代号B) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.12.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 20 | 20 | 热稳定性试验环境空气温度(代号C) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.12.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||
| 21 | 21 | 热稳定性试验环境空气温度(代号D) | 《高压直流输电系统用并联电容器及交流滤波电容器》GB/T20994-2007 2.12.2 Shunt capacitors and AC filter capacitors for HVDC transmission systems | ||||