| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 | 1 | 无线电干扰电压 | 040501 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 11.4 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) 引用方法:GB/T 11604-1989 | ||
| 2 | 2 | 压力漏增 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 9.2.2、11.5.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 3 | 3 | 最小爬电比距 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 6.7 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 4 | 4 | 抗张强度 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 5 | 5 | 断裂伸长率 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 6 | 6 | 抗撕裂强度 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 7 | 7 | 硬度 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 8 | 8 | 压缩永久变形 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 9 | 9 | 抗张强度最大变化率 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 10 | 10 | 伸长率最大变化率 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 11 | 11 | 体积电阻率(23℃) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2、表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 12 | 12 | tanδ | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2、表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 13 | 13 | 介电常数 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2、表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 14 | 14 | 短时工频击穿电场强度 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表A.1、表A.2、表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 15 | 15 | 体积电阻率 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 16 | 16 | 热变形温度 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表B.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 17 | 17 | 动力黏度(25℃) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 18 | 18 | 黏度最大变化率 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 19 | 19 | 闪点 | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 20 | 20 | 折光指数(25℃) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 21 | 21 | 击穿电压(电极间距2.5mm) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 22 | 22 | 体积电阻率(25℃) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||
| 23 | 23 | 挥发度(150℃,3h) | 040599 | 《额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:额定电压500kV(Um=550kV)交联聚乙烯绝缘电力电缆附件》GB/T22078.3-2008 表C.1 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV)—Part 3: Accessories for power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV) | |||