| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 电气用热固性树脂工业 硬质玻璃纤维缠绕管 | 1 | 标称外径允许偏差 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.1 表2 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes | |||
| 2 | 2 | 标称内径允许偏差 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.2 表3 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes | ||||
| 3 | 3 | 标称壁厚允许偏差 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.3 表4 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes | ||||
| 4 | 4 | 平直度(最大间隙) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.4 表5 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes | ||||
| 5 | 5 | 垂直层向弯曲强度(常态) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中5.1 | ||||
| 6 | 6 | 垂直层向弯曲强度(155°C下) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中5.1 | ||||
| 7 | 7 | 轴向压缩强度 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中5.2 | ||||
| 8 | 8 | 层间粘合强度 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中5.3 | ||||
| 9 | 9 | 平行层向击穿电压(90±2)°C油中 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 10 | 10 | 垂直层向电气强度(90±2)°C油中 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6(见表7) Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 11 | 11 | 受潮后沿面耐电压(5min) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:GB/T 1408.1—2006 中10.6 | ||||
| 12 | 12 | 浸水后绝缘电阻 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中6.2 | ||||
| 13 | 13 | 工频下介质损耗因数 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中6.3 | ||||
| 14 | 14 | 工频下相对电容率 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中6.3 | ||||
| 15 | 15 | 温度指数(T·I) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 60212-2:2006 中7.1 | ||||
| 16 | 16 | 吸水性 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中7.2 | ||||
| 17 | 17 | 密度 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中7.3 | ||||
| 18 | 18 | 燃烧性 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中7.4 | ||||
| 19 | 19 | 局部放电 | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表6 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:GB/T 7354—2003《》 | ||||
| 20 | 20 | 垂直层向电气强度(标称壁厚1.0mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 21 | 21 | 垂直层向电气强度(标称壁厚1.2mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 22 | 22 | 垂直层向电气强度(标称壁厚1.4mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 23 | 23 | 垂直层向电气强度(标称壁厚1.6mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 24 | 24 | 垂直层向电气强度(标称壁厚1.8mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 25 | 25 | 垂直层向电气强度(标称壁厚2.0mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 26 | 26 | 垂直层向电气强度(标称壁厚2.2mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 27 | 27 | 垂直层向电气强度(标称壁厚2.4mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 28 | 28 | 垂直层向电气强度(标称壁厚2.6mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 29 | 29 | 垂直层向电气强度(标称壁厚2.8mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||
| 30 | 30 | 垂直层向电气强度(标称壁厚≥3.0mm) | 《电气用热固性树脂工业 硬质玻璃纤维缠绕管》GB/T23100-2008 4.5 表7 Industrial rigid round winded tubes based on thermosetting resins for electrical purposes 引用方法:IEC 61212-2:2006 中第6章 | ||||