| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑用轻质隔墙条板 | 1 | 含水率 | 《建筑用轻质隔墙条板》GB/T23451-2023 5.2 表2、6.3 表6 序号10 Lightweight panels for partition wall used in buildings | |||
| 2 | 2 | 板面外露筋、露网格布;飞边毛刺;板面泛霜返碱;贯通性裂缝 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号1 Lightweight panels for partition wall used in buildings | ||||
| 3 | 3 | 复合条板面层脱落 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号2 Lightweight panels for partition wall used in buildings | ||||
| 4 | 4 | 板面裂缝(长度50mm~100mm,宽度0.5mm~1.0mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号3 Lightweight panels for partition wall used in buildings | ||||
| 5 | 5 | 板面蜂窝气孔(长径5mm~10mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号4 Lightweight panels for partition wall used in buildings | ||||
| 6 | 6 | 板面蜂窝气孔(长径5mm~30mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号4 Lightweight panels for partition wall used in buildings | ||||
| 7 | 7 | 缺棱掉角(宽度×长度10mm×25mm~20mm×30mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.1 表3 序号5 Lightweight panels for partition wall used in buildings | ||||
| 8 | 8 | 长度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号1 Lightweight panels for partition wall used in buildings | ||||
| 9 | 9 | 宽度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号2 Lightweight panels for partition wall used in buildings | ||||
| 10 | 10 | 厚度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号3 Lightweight panels for partition wall used in buildings | ||||
| 11 | 11 | 板面平整度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号4 Lightweight panels for partition wall used in buildings | ||||
| 12 | 12 | 对角线差 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号5 Lightweight panels for partition wall used in buildings | ||||
| 13 | 13 | 侧向弯曲 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.1 表4 序号6 Lightweight panels for partition wall used in buildings | ||||
| 14 | 14 | 单排孔空心板孔间肋厚和面层壁厚(板厚≤120mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.2 表5 序号1 Lightweight panels for partition wall used in buildings | ||||
| 15 | 15 | 单排孔空心板孔间肋厚和面层壁厚(板厚≥150mm) | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.2 表5 序号1 Lightweight panels for partition wall used in buildings | ||||
| 16 | 16 | 多排孔空心板孔间肋厚和面层壁厚 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.2 表5 序号2 Lightweight panels for partition wall used in buildings | ||||
| 17 | 17 | 烧结条板孔间肋厚 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.2 表5 注a Lightweight panels for partition wall used in buildings | ||||
| 18 | 18 | 烧结条板面层壁厚 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.2.2 表5 注b Lightweight panels for partition wall used in buildings | ||||
| 19 | 19 | 面密度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号1 Lightweight panels for partition wall used in buildings 引用方法:GB/T 30100《建筑墙板试验方法》 | ||||
| 20 | 20 | 抗压强度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号2 Lightweight panels for partition wall used in buildings 引用方法:GB/T 30100《建筑墙板试验方法》 | ||||
| 21 | 21 | 抗弯荷载 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号3 Lightweight panels for partition wall used in buildings | ||||
| 22 | 22 | 抗冲击性能 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号4 Lightweight panels for partition wall used in buildings 引用方法:GB/T 30100《建筑墙板试验方法》 | ||||
| 23 | 23 | 吊挂力 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号5 Lightweight panels for partition wall used in buildings | ||||
| 24 | 24 | 空气声计权隔声量 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号6 Lightweight panels for partition wall used in buildings 引用方法:GB/T 19889.3《声学 建筑和建筑构件隔声测量 第3部分:建筑构件空气声隔声的实验室测量》 | ||||
| 25 | 25 | 耐火极限 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号7 Lightweight panels for partition wall used in buildings 引用方法:GB/T 9978.1、GB/T 9978.8 | ||||
| 26 | 26 | 传热系数 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号8 Lightweight panels for partition wall used in buildings 引用方法:GB/T 13475《绝热 稳态传热性质的测定 标定和防护热箱法》 | ||||
| 27 | 27 | 软化系数 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号9 Lightweight panels for partition wall used in buildings 引用方法:GB/T 30100《建筑墙板试验方法》 | ||||
| 28 | 28 | 干燥收缩值 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号11 Lightweight panels for partition wall used in buildings 引用方法:GB/T 30100《建筑墙板试验方法》 | ||||
| 29 | 29 | 防潮石膏条板2h吸水率 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号12 Lightweight panels for partition wall used in buildings | ||||
| 30 | 30 | 复合条板面板垂直于板面的抗拉强度 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号13 Lightweight panels for partition wall used in buildings | ||||
| 31 | 31 | 烧结条板5h沸煮吸水率 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号14 Lightweight panels for partition wall used in buildings 引用方法:GB/T 2542《砌墙砖试验方法》 | ||||
| 32 | 32 | 烧结条板石灰爆裂 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号15 Lightweight panels for partition wall used in buildings 引用方法:GB/T 2542《砌墙砖试验方法》 | ||||
| 33 | 33 | 烧结条板泛霜 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.3 表6 序号16 Lightweight panels for partition wall used in buildings 引用方法:GB/T 2542《砌墙砖试验方法》 | ||||
| 34 | 34 | 放射性核素限量 | 《建筑用轻质隔墙条板》GB/T23451-2023 6.4 Lightweight panels for partition wall used in buildings 引用方法:GB 6566《建筑材料放射性核素限量》 | ||||