项目
限值 / 检出限 / 定量限
单位
出处
弯曲弹性模量
SMC/BMC复合材料≥ 8500 MPa (UP-SMC-20a)
≥ 8500 MPa (UP-SMC-20b)
≥ 10000 MPa (UP-SMC-25a)
≥ 9000 MPa (UP-SMC-25b)
≥ 9000 MPa (UP-SMC-25c)
≥ 9500 MPa (UP-SMC-25d)
≥ 9500 MPa (UP-SMC-30a)
≥ 9500 MPa (UP-SMC-30b)
≥ 9500 MPa (UP-SMC-30c)
≥ 18000 MPa (UP-SMC-35a)
≥ 9500 MPa (VE-SMC-25a)
≥ 13000 MPa (VE-SMC-50a)
≥ 25000 MPa (VE-SMC-50b)
≥ 9000 MPa (UP-BMC-10a)
≥ 9000 MPa (UP-BMC-10b)
≥ 11000 MPa (UP-BMC-15a)
≥ 11000 MPa (UP-BMC-15b)
≥ 12000 MPa (UP-BMC-20a)
≥ 12000 MPa (UP-BMC-20b)
≥ 12500 MPa (UP-BMC-25a)
≥ 12500 MPa (UP-BMC-25b)
≥ 12500 MPa (UP-BMC-25c)
≥ 11000 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.1
弯曲强度
SMC/BMC复合材料≥ 50 MPa (UP-SMC-20a)
≥ 50 MPa (UP-SMC-20b)
≥ 60 MPa (UP-SMC-25a)
≥ 55 MPa (UP-SMC-25b)
≥ 55 MPa (UP-SMC-25c)
≥ 55 MPa (UP-SMC-25d)
≥ 65 MPa (UP-SMC-30a)
≥ 65 MPa (UP-SMC-30b)
≥ 65 MPa (UP-SMC-30c)
≥ 200 MPa (UP-SMC-35a)
≥ 80 MPa (VE-SMC-25a)
≥ 160 MPa (VE-SMC-50a)
≥ 320 MPa (VE-SMC-50b)
≥ 18 MPa (UP-BMC-10a)
≥ 20 MPa (UP-BMC-10b)
≥ 22 MPa (UP-BMC-15a)
≥ 25 MPa (UP-BMC-15b)
≥ 25 MPa (UP-BMC-20a)
≥ 30 MPa (UP-BMC-20b)
≥ 30 MPa (UP-BMC-25a)
≥ 30 MPa (UP-BMC-25b)
≥ 25 MPa (UP-BMC-25c)
≥ 30 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.2
弯曲弹性模量保留率
SMC/BMC复合材料≥ 1.8 % (UP-SMC-20a)
≥ 1.8 % (UP-SMC-20b)
≥ 2.0 % (UP-SMC-25a)
≥ 2.0 % (UP-SMC-25b)
≥ 2.0 % (UP-SMC-25c)
≥ 2.0 % (UP-SMC-25d)
≥ 2.0 % (UP-SMC-30a)
≥ 2.0 % (UP-SMC-30b)
≥ 2.0 % (UP-SMC-30c)
≥ 2.0 % (UP-SMC-35a)
≥ 1.4 % (VE-SMC-25a)
≥ 1.8 % (VE-SMC-50a)
≥ 1.8 % (VE-SMC-50b)
≥ 0.3 % (UP-BMC-10a)
≥ 0.4 % (UP-BMC-10b)
≥ 0.4 % (UP-BMC-15a)
≥ 0.5 % (UP-BMC-15b)
≥ 0.4 % (UP-BMC-20a)
≥ 0.5 % (UP-BMC-20b)
≥ 0.5 % (UP-BMC-25a)
≥ 0.5 % (UP-BMC-25b)
≥ 0.5 % (UP-BMC-25c)
≥ 0.4 % (VE-BMC-25a)%表2/表3/表4/表5/表6 1.3
压缩弹性模量
SMC/BMC复合材料≥ 9000 MPa (UP-SMC-20a)
≥ 9000 MPa (UP-SMC-20b)
≥ 9500 MPa (UP-SMC-25a)
≥ 9000 MPa (UP-SMC-25b)
≥ 9500 MPa (UP-SMC-25c)
≥ 9500 MPa (UP-SMC-25d)
≥ 10000 MPa (UP-SMC-30a)
≥ 10000 MPa (UP-SMC-30b)
≥ 10000 MPa (UP-SMC-30c)
≥ 16000 MPa (UP-SMC-35a)
≥ 9500 MPa (VE-SMC-25a)
≥ 12000 MPa (VE-SMC-50a)
≥ 21000 MPa (VE-SMC-50b)
≥ 9000 MPa (UP-BMC-10a)
≥ 10000 MPa (UP-BMC-10b)
≥ 10000 MPa (UP-BMC-15a)
≥ 10000 MPa (UP-BMC-15b)
≥ 10000 MPa (UP-BMC-20a)
≥ 10000 MPa (UP-BMC-20b)
≥ 10000 MPa (UP-BMC-25a)
≥ 10500 MPa (UP-BMC-25b)
≥ 10500 MPa (UP-BMC-25c)
≥ 9000 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.4
压缩强度
SMC/BMC复合材料≥ 160 MPa (UP-SMC-20a)
≥ 160 MPa (UP-SMC-20b)
≥ 170 MPa (UP-SMC-25a)
≥ 160 MPa (UP-SMC-25b)
≥ 160 MPa (UP-SMC-25c)
≥ 160 MPa (UP-SMC-25d)
≥ 160 MPa (UP-SMC-30a)
≥ 160 MPa (UP-SMC-30b)
≥ 160 MPa (UP-SMC-30c)
≥ 280 MPa (UP-SMC-35a)
≥ 150 MPa (VE-SMC-25a)
≥ 250 MPa (VE-SMC-50a)
≥ 450 MPa (VE-SMC-50b)
≥ 85 MPa (UP-BMC-10a)
≥ 90 MPa (UP-BMC-10b)
≥ 100 MPa (UP-BMC-15a)
≥ 120 MPa (UP-BMC-15b)
≥ 120 MPa (UP-BMC-20a)
≥ 140 MPa (UP-BMC-20b)
≥ 120 MPa (UP-BMC-25a)
≥ 140 MPa (UP-BMC-25b)
≥ 120 MPa (UP-BMC-25c)
≥ 100 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.5
拉伸弹性模量
SMC/BMC复合材料≥ 9000 MPa (UP-SMC-20a)
≥ 9000 MPa (UP-SMC-20b)
≥ 10000 MPa (UP-SMC-25a)
≥ 9500 MPa (UP-SMC-25b)
≥ 9500 MPa (UP-SMC-25c)
≥ 9500 MPa (UP-SMC-25d)
≥ 10000 MPa (UP-SMC-30a)
≥ 10000 MPa (UP-SMC-30b)
≥ 9500 MPa (UP-SMC-30c)
≥ 18000 MPa (UP-SMC-35a)
≥ 9500 MPa (VE-SMC-25a)
≥ 12000 MPa (VE-SMC-50a)
≥ 24000 MPa (VE-SMC-50b)
≥ 7000 MPa (UP-BMC-10a)
≥ 7000 MPa (UP-BMC-10b)
≥ 8000 MPa (UP-BMC-15a)
≥ 9000 MPa (UP-BMC-15b)
≥ 9000 MPa (UP-BMC-20a)
≥ 10000 MPa (UP-BMC-20b)
≥ 10000 MPa (UP-BMC-25a)
≥ 10500 MPa (UP-BMC-25b)
≥ 9500 MPa (UP-BMC-25c)
≥ 9500 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.6
拉伸强度
SMC/BMC复合材料≥ 150 MPa (UP-SMC-20a)
≥ 150 MPa (UP-SMC-20b)
≥ 180 MPa (UP-SMC-25a)
≥ 160 MPa (UP-SMC-25b)
≥ 170 MPa (UP-SMC-25c)
≥ 170 MPa (UP-SMC-25d)
≥ 180 MPa (UP-SMC-30a)
≥ 180 MPa (UP-SMC-30b)
≥ 170 MPa (UP-SMC-30c)
≥ 220 MPa (UP-SMC-35a)
≥ 160 MPa (VE-SMC-25a)
≥ 280 MPa (VE-SMC-50a)
≥ 450 MPa (VE-SMC-50b)
≥ 55 MPa (UP-BMC-10a)
≥ 60 MPa (UP-BMC-10b)
≥ 85 MPa (UP-BMC-15a)
≥ 90 MPa (UP-BMC-15b)
≥ 90 MPa (UP-BMC-20a)
≥ 140 MPa (UP-BMC-20b)
≥ 120 MPa (UP-BMC-25a)
≥ 140 MPa (UP-BMC-25b)
≥ 120 MPa (UP-BMC-25c)
≥ 100 MPa (VE-BMC-25a)MPa表2/表3/表4/表5/表6 1.7
简支梁冲击强度
SMC/BMC复合材料≥ 60 kJ/m² (UP-SMC-20a)
≥ 60 kJ/m² (UP-SMC-20b)
≥ 75 kJ/m² (UP-SMC-25a)
≥ 70 kJ/m² (UP-SMC-25b)
≥ 70 kJ/m² (UP-SMC-25c)
≥ 70 kJ/m² (UP-SMC-25d)
≥ 80 kJ/m² (UP-SMC-30a)
≥ 80 kJ/m² (UP-SMC-30b)
≥ 75 kJ/m² (UP-SMC-30c)
≥ 180 kJ/m² (UP-SMC-35a)
≥ 80 kJ/m² (VE-SMC-25a)
≥ 150 kJ/m² (VE-SMC-50a)
≥ 280 kJ/m² (VE-SMC-50b)
≥ 10 kJ/m² (UP-BMC-10a)
≥ 10 kJ/m² (UP-BMC-10b)
≥ 25 kJ/m² (UP-BMC-15a)
≥ 25 kJ/m² (UP-BMC-15b)
≥ 25 kJ/m² (UP-BMC-20a)kJ/m²表2/表3/表4/表5/表6 1.8