| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 额定电压1.8/3kV及以下风力发电用耐扭曲软电缆 | 1 | 电缆正常运行时导体最高温度 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | ||
| 2 | 2 | 最小弯曲半径 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.3 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 3 | 3 | 环境温度(运行时) | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 4 | 4 | 环境温度(敷设时) | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 5 | 5 | 导体最高温度(正常运行时) | 040503 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.5 表1 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 6 | 6 | 导体最高温度(短路时,最长持续5s) | 040503 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.5 表1 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 7 | 7 | 正常运行时导体最高温度 | 040503 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 4.6 表2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 8 | 8 | 绝缘标称厚度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.2.2 表6 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 9 | 9 | 火花试验电压 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.2.4 表7 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T 3048.9 | |||
| 10 | 10 | 编织用软铜圆线或镀锡圆铜线的标称直径 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.4 表8 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 11 | 11 | 最外层绞合节距 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.3 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 12 | 12 | 成品电缆标志间距 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.7 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 13 | 13 | 数字识别标志间距di | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 6.2.6.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 14 | 14 | 绝缘厚度平均值 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-201 | |||
| 15 | 15 | 绝缘厚度最小测量值 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-201 | |||
| 16 | 16 | 护套厚度平均值 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-202 | |||
| 17 | 17 | 护套厚度最小测量值 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-202 | |||
| 18 | 18 | 缆芯绞合节距 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.3 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T4909.2 | |||
| 19 | 19 | 金属屏蔽用软圆铜线或镀锡圆铜线直径 | 040509 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T4909.2 | |||
| 20 | 20 | 金属编织(或缠绕)密度 | 040509 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T4909.2 | |||
| 21 | 21 | 成品电缆平均外径 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.2.5 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-203 | |||
| 22 | 22 | 导体直流电阻(20℃) | 040503 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.3 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.4 | |||
| 23 | 23 | 绝缘电阻(20℃) | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.5 | |||
| 24 | 24 | 绝缘电阻(额定工作温度90℃) | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.5 | |||
| 25 | 25 | 绝缘电阻(额定工作温度105℃) | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.5 | |||
| 26 | 26 | 成品电缆电压试验 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.5 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.8 | |||
| 27 | 27 | 绝缘线芯电压试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.6 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.8 | |||
| 28 | 28 | 4h电压试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.7 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.8 | |||
| 29 | 29 | 冲击电压试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.8 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T3048.13 | |||
| 30 | 30 | 绝缘老化前后机械性能 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.9 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-401、IEC60811-501 | |||
| 31 | 31 | 护套老化前后机械性能 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.10 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-401、IEC60811-501 | |||
| 32 | 32 | 护套高温压力试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.11 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-508 | |||
| 33 | 33 | 护套低温性能试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.12 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-505、IEC60811-506 | |||
| 34 | 34 | 护套抗开裂试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.13 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-509 | |||
| 35 | 35 | 绝缘耐臭氧试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.14 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-403 | |||
| 36 | 36 | 绝缘和护套热延伸试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.15 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-507 | |||
| 37 | 37 | 护套浸油试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.16 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-404 | |||
| 38 | 38 | 绝缘和护套抗撕试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.17 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:JB/T10696.7 | |||
| 39 | 39 | 常温扭转试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.18 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 40 | 40 | 低温扭转试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.18 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 41 | 41 | 高温扭转试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.18 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 42 | 42 | 负载扭转试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.18 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 43 | 43 | 负重试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.19 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 44 | 44 | 低温弯曲试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.20 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 45 | 45 | 人工气候老化试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.21 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 46 | 46 | 盐雾试验 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.22 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 47 | 47 | 电缆单根燃烧试验 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.23 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T18380.12 | |||
| 48 | 48 | 电缆成束燃烧试验 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.24 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T18380.35 | |||
| 49 | 49 | 成品电缆标志 | 040501 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.25 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T6995.1 | |||
| 50 | 50 | 绝缘线芯识别 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 7.25 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T6995.1 | |||
| 51 | 51 | 交货长度计量误差 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 9.1 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 52 | 52 | 抗张强度变化率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 53 | 53 | 断裂伸长率变化率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine | |||
| 54 | 54 | 热延伸试验温度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-507 | |||
| 55 | 55 | 热延伸试验机械应力 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-507 | |||
| 56 | 56 | 载荷下最大伸长率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-507 | |||
| 57 | 57 | 冷却后最大永久伸长率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-507 | |||
| 58 | 58 | 抗撕强度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:JB/T10696.7 | |||
| 59 | 59 | 高温压力试验温度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-508 | |||
| 60 | 60 | 高温压力试验压痕中间值/平均厚度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-508 | |||
| 61 | 61 | 抗开裂试验温度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-509 | |||
| 62 | 62 | 抗开裂试验持续时间 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-509 | |||
| 63 | 63 | 抗开裂试验结果 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-509 | |||
| 64 | 64 | 低温拉伸试验温度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-504 | |||
| 65 | 65 | 低温拉伸未断裂时的伸长率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-504 | |||
| 66 | 66 | 低温冲击试验温度 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-505 | |||
| 67 | 67 | 低温冲击试验结果 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 表A.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-505 | |||
| 68 | 68 | 人工气候老化后抗张强度变化率TS1 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 F.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-501 | |||
| 69 | 69 | 人工气候老化后断裂伸长率变化率EB1 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 F.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-501 | |||
| 70 | 70 | 人工气候老化后抗张强度变化率TS2 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 F.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-501 | |||
| 71 | 71 | 人工气候老化后断裂伸长率变化率EB2 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 F.4 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:IEC60811-501 | |||
| 72 | 72 | 盐雾试验后抗张强度变化率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 G.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T2423.17 | |||
| 73 | 73 | 盐雾试验后断裂伸长率变化率 | 040599 | 《额定电压1.8/3kV及以下风力发电用耐扭曲软电缆》GB/T29631-2025 G.2 Flexible and torsion resistant cables of rated voltages up to and including 1.8/3kV for wind turbine 引用方法:GB/T2423.17 | |||