| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 静音管网叠压给水设备 | 1 | 设备运行流量 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.3 Water supply equipment of low voice additive pipe pressure | |||
| 2 | 2 | 设备运行扬程 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.3 Water supply equipment of low voice additive pipe pressure | ||||
| 3 | 3 | 压力控制误差 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.7 Water supply equipment of low voice additive pipe pressure | ||||
| 4 | 4 | 水泵自动切换设定时间误差 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.8 Water supply equipment of low voice additive pipe pressure | ||||
| 5 | 5 | 连续运行时间 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.9 表1 Water supply equipment of low voice additive pipe pressure | ||||
| 6 | 6 | 备用泵自动投入运行时间 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.11 Water supply equipment of low voice additive pipe pressure | ||||
| 7 | 7 | 设备耐压强度 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.14 Water supply equipment of low voice additive pipe pressure | ||||
| 8 | 8 | 噪声 | 《静音管网叠压给水设备》GB/T31894-2015 7.2.15 Water supply equipment of low voice additive pipe pressure 引用方法:JB/T 8098—1999《泵的噪音测量与评价方法》 | ||||
| 9 | 9 | 稳流补偿罐设计压力 | 《静音管网叠压给水设备》GB/T31894-2015 7.3.1 Water supply equipment of low voice additive pipe pressure | ||||
| 10 | 10 | 稳流补偿罐封头公称厚度 | 《静音管网叠压给水设备》GB/T31894-2015 7.3.4 Water supply equipment of low voice additive pipe pressure | ||||
| 11 | 11 | 稳流补偿罐焊缝高度 | 《静音管网叠压给水设备》GB/T31894-2015 7.3.5 Water supply equipment of low voice additive pipe pressure | ||||
| 12 | 12 | 气压罐设计压力 | 《静音管网叠压给水设备》GB/T31894-2015 7.5 a) Water supply equipment of low voice additive pipe pressure 引用方法:GB 150.1、GB 150.2、GB 150.3、GB 150.4 | ||||
| 13 | 13 | 气压罐承压等级 | 《静音管网叠压给水设备》GB/T31894-2015 7.5 a) Water supply equipment of low voice additive pipe pressure | ||||
| 14 | 14 | 气压罐水容积 | 《静音管网叠压给水设备》GB/T31894-2015 7.5 b) Water supply equipment of low voice additive pipe pressure | ||||
| 15 | 15 | 逆流补偿器承压 | 《静音管网叠压给水设备》GB/T31894-2015 7.6 c) Water supply equipment of low voice additive pipe pressure | ||||
| 16 | 16 | 屏蔽式稳流套管直径 | 《静音管网叠压给水设备》GB/T31894-2015 7.7.1 表4 Water supply equipment of low voice additive pipe pressure | ||||
| 17 | 17 | 屏蔽式稳流套管长度 | 《静音管网叠压给水设备》GB/T31894-2015 7.7.1 表4 Water supply equipment of low voice additive pipe pressure | ||||
| 18 | 18 | 备用泵供水能力 | 《静音管网叠压给水设备》GB/T31894-2015 7.8.3 Water supply equipment of low voice additive pipe pressure 引用方法:GB/T 2816《井用潜水泵》 | ||||
| 19 | 19 | 电机防护等级 | 《静音管网叠压给水设备》GB/T31894-2015 7.8.5 Water supply equipment of low voice additive pipe pressure 引用方法:GB 4208《外壳防护等级(IP 代码)》 | ||||
| 20 | 20 | 管壁厚 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.2 Water supply equipment of low voice additive pipe pressure 引用方法:GB/T 12771《流体输送用不锈钢焊接钢管》 | ||||
| 21 | 21 | 熔深 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.2 Water supply equipment of low voice additive pipe pressure | ||||
| 22 | 22 | 滤网尺寸 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.5 Water supply equipment of low voice additive pipe pressure | ||||
| 23 | 23 | 过滤网过滤总面积 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.5 Water supply equipment of low voice additive pipe pressure | ||||
| 24 | 24 | 压力真空表和压力传感器精度 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.7 Water supply equipment of low voice additive pipe pressure | ||||
| 25 | 25 | 进水侧压力真空表和压力传感器量程 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.7 Water supply equipment of low voice additive pipe pressure | ||||
| 26 | 26 | 出水侧压力传感器量程 | 《静音管网叠压给水设备》GB/T31894-2015 7.9.7 Water supply equipment of low voice additive pipe pressure | ||||
| 27 | 27 | 控制柜防护等级 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.1.10 Water supply equipment of low voice additive pipe pressure 引用方法:GB 4208《外壳防护等级(IP 代码)》 | ||||
| 28 | 28 | 绝缘电阻 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.2 a) Water supply equipment of low voice additive pipe pressure 引用方法:GB/T 3797—2005 中4.8.1、5.2.4 | ||||
| 29 | 29 | 主接地点电阻 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.3 c) Water supply equipment of low voice additive pipe pressure | ||||
| 30 | 30 | 低温试验 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.6 Water supply equipment of low voice additive pipe pressure | ||||
| 31 | 31 | 高温试验 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.7 Water supply equipment of low voice additive pipe pressure | ||||
| 32 | 32 | 恒定湿热试验 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.8 Water supply equipment of low voice additive pipe pressure | ||||
| 33 | 33 | 抗干扰能力 | 《静音管网叠压给水设备》GB/T31894-2015 7.10.3.5 Water supply equipment of low voice additive pipe pressure | ||||