| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 钢框架发泡水泥芯材复合板 | 1 | 露筋 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.1 表2 The steel frame composite panels made from foamed cement | ||
| 2 | 2 | 孔洞 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.1 表2 The steel frame composite panels made from foamed cement | |||
| 3 | 3 | 蜂窝 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.1 表2 The steel frame composite panels made from foamed cement | |||
| 4 | 4 | 裂缝 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.1 表2 The steel frame composite panels made from foamed cement | |||
| 5 | 5 | 露网 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.1 表2 The steel frame composite panels made from foamed cement | |||
| 6 | 6 | 板长偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 7 | 7 | 板宽偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 8 | 8 | 板厚偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 9 | 9 | 边肋高度偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 10 | 10 | 对角线偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 11 | 11 | 翘曲 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 12 | 12 | 侧向弯曲 | 100102 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 13 | 13 | 预埋钢板中心线位置偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 14 | 14 | 预埋钢板平整度 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 15 | 15 | 预留洞口中心线位置偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 16 | 16 | 预留洞口制作尺寸偏差 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.2 表3 The steel frame composite panels made from foamed cement | |||
| 17 | 17 | 外加荷载值 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.1.1 表4、6.3.1.1.2 表5、6.3.1.1.3 表6 等4处 The steel frame composite panels made from foamed cement | |||
| 18 | 18 | 挠度允许值 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.1.1 表4、6.3.1.1.2 表5、6.3.1.1.3 表6 等4处 The steel frame composite panels made from foamed cement | |||
| 19 | 19 | 吊挂力 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 23451《建筑用轻质隔墙条板》 | |||
| 20 | 20 | 抗冲击性能 | 100102 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 23451《建筑用轻质隔墙条板》 | |||
| 21 | 21 | 传热系数 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.3 The steel frame composite panels made from foamed cement 引用方法:GB/T 13475《绝热 稳态传热性质的测定 标定和防护热箱法》 | |||
| 22 | 22 | 耐火时间 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.3 The steel frame composite panels made from foamed cement 引用方法:GB/T 9978.1《建筑构件耐火试验方法 第1部分:通用要求》 | |||
| 23 | 23 | 空气声计权隔声量 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.1.3 The steel frame composite panels made from foamed cement 引用方法:GB/T 19889.3《声学 建筑和建筑构件隔声测量 第3部分:建筑构件空气声隔声的实验室测量》 | |||
| 24 | 24 | 体积(干)密度 | 100101 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 11969《蒸压加气混凝土性能试验方法》 | |||
| 25 | 25 | 导热系数 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 10294《绝热材料稳态热阻及有关特性的测定 防护热板法》 | |||
| 26 | 26 | 抗压强度 | 100102 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 11969《蒸压加气混凝土性能试验方法》 | |||
| 27 | 27 | 体积吸水率 | 100101 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 5486《无机硬质绝热制品试验方法》 | |||
| 28 | 28 | 软化系数 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB/T 11969《蒸压加气混凝土性能试验方法》 | |||
| 29 | 29 | 燃烧性能 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.3.2 The steel frame composite panels made from foamed cement 引用方法:GB 8624《建筑材料及制品燃烧性能分级》 | |||
| 30 | 30 | 放射性核素限量 | 100199 | 《钢框架发泡水泥芯材复合板》GB/T33499-2017 6.4 The steel frame composite panels made from foamed cement 引用方法:GB 6566《建筑材料放射性核素限量》 | |||