| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑采光顶 气密、水密、抗风压性能 | 1 | 单位面积空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.1、4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | |||
| 2 | 2 | 单位开启缝长空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 3 | 3 | 附加空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 4 | 4 | 附加空气渗透量与固定部分空气渗透量之和 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 5 | 5 | 总空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 6 | 6 | 整体试件(含可开启部分)空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 7 | 7 | 可开启部分空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 8 | 8 | 可开启部分单位开启缝长空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 9 | 9 | 10 Pa压力差下单位面积空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.2 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 10 | 10 | 10 Pa压力差下单位开启缝长空气渗透量 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.4.3.2 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 11 | 11 | 水密性能(渗漏) | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.5.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 12 | 12 | 面法线挠度 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.6.4.1 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 13 | 13 | 结构损坏或功能障碍 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.9.2 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||
| 14 | 14 | 压力作用时间 | 《建筑采光顶 气密、水密、抗风压性能检测方法》GB/T34555-2017 4.9.3 Test method of air permeability, watertightness, wind load resistance performance for building skylight system | ||||