| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端 | 1 | 绝缘标称厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.2 表6 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | ||
| 2 | 2 | 铜护套标称厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.2 表6 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 3 | 3 | 单芯绝缘标称厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.2 表7 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 4 | 4 | 多芯绝缘标称厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.2 表7 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 5 | 5 | 绝缘电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.3 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 3048.5—2007《电线电缆电性能试验方法 第5部分:绝缘电阻试验》 | |||
| 6 | 6 | 工作温度下绝缘电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.2.3、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 7 | 7 | 保护层平均厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.3.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 8 | 8 | 铜护套厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 5.4.3、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 9 | 9 | 导体直流电阻 | 040503 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 7.1、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 3048.4—2007《电线电缆电性能试验方法 第4部分:导体直流电阻试验》 | |||
| 10 | 10 | 金属护套直流电阻 | 040509 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 7.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 3048.4—2007《电线电缆电性能试验方法 第4部分:导体直流电阻试验》 | |||
| 11 | 11 | 电压试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 7.3、表16、表17 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 12 | 12 | 气密性 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 7.4 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 13 | 13 | 绝缘厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.4.1、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 14 | 14 | 金属护套弯曲试验 | 040509 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.5.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 15 | 15 | 弯曲后电压试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.5.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 16 | 16 | 金属护套压扁试验 | 040509 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.6.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 17 | 17 | 压扁系数 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.6.1 表13 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 18 | 18 | 压扁后电压试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.6.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 19 | 19 | 平均外径 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 8.7.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 20 | 20 | 0.6/1 kV电缆4 h电压试验 | 040501 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 9.4、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 3048.8—2007《电线电缆电性能试验方法 第8部分:交流电压试验》 | |||
| 21 | 21 | 耐火试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 10.5 表14、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:BS 6387:2013 | |||
| 22 | 22 | 终端电压试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 11.1.4 表15 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 23 | 23 | 环境温度下绝缘电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 11.2.3、表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 3048.5—2007《电线电缆电性能试验方法 第5部分:绝缘电阻试验》 | |||
| 24 | 24 | 接地连续性电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 11.3.3 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 25 | 25 | 导体尺寸 | 040503 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 26 | 26 | 保护层厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 27 | 27 | 护套直流电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 28 | 28 | 气密性试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 29 | 29 | 弯曲试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 30 | 30 | 压扁试验 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表16 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 31 | 31 | 环境温度下绝缘电阻测量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表17 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 32 | 32 | 接地连续性 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表17 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 33 | 33 | 云母带厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第5章 | |||
| 34 | 34 | 云母含量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第8章 | |||
| 35 | 35 | 挥发物含量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第8章 | |||
| 36 | 36 | 胶粘剂含量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第8章 | |||
| 37 | 37 | 外观 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 38 | 38 | 宽度公差 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 39 | 39 | 拉伸强度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第10章 | |||
| 40 | 40 | 介电强度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第22章 | |||
| 41 | 41 | 体积电阻率 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 5019.2—2009中第25章 | |||
| 42 | 42 | 高温下电性能耐电压,1kV,1min | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 43 | 43 | 高温下电性能绝缘电阻 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 44 | 44 | 盘卷管芯直径 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 45 | 45 | 管壁厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 46 | 46 | 卷盘直径 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 47 | 47 | 接头数 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 48 | 48 | 储存期 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.1、表B.2 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV | |||
| 49 | 49 | 电导率 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 17650.2—1998《取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度》 | |||
| 50 | 50 | 卤酸气体释出量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 17650.2—1998《取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度》 | |||
| 51 | 51 | pH值 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 17650.2—1998《取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度》 | |||
| 52 | 52 | 氟含量 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:IEC 60684-2:2011《绝缘软管 第2部分:绝缘软管(Flexible insulating sleeving—Part 2: Methods of test)》 | |||
| 53 | 53 | 低毒性 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表B.2、表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 20285—2006中安全级ZA2 | |||
| 54 | 54 | 厚度 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 451.3—2002 | |||
| 55 | 55 | 伸长率 | 040599 | 《额定电压 0.6/1 kV 及以下云母带矿物绝缘波纹铜护套电缆及终端》GB/T34926-2017 表C.1 Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV 引用方法:GB/T 12914—2008 | |||