| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 城镇供热预制直埋保温阀门技术要求 | 1 | 未保温阀杆长度M | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 4.4 Technical requirements for pre-insulated directly buried valve of urban heating | |||
| 2 | 2 | 外护管端面与轴线角度偏差 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.2 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 3 | 3 | 外护管最小壁厚 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.3 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 4 | 4 | 外护管密度 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.4 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 5 | 5 | 炭黑弥散度(结块、气泡、空洞或杂质尺寸) | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.5 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 6 | 6 | 炭黑含量 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.6 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 7 | 7 | 拉伸屈服强度 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.7 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 8 | 8 | 断裂伸长率 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.7 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 9 | 9 | 纵向回缩率 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.8 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 10 | 10 | 耐环境应力开裂失效时间 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.9 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 11 | 11 | 熔体质量流动速率(MFR) | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.10 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 12 | 12 | 氧化诱导时间(热稳定性) | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.11 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 13 | 13 | 焊接熔体质量流动速率差值 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.12 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 14 | 14 | 纵焊缝错开弧长距离 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.2.13 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 15 | 15 | 径向泡孔平均尺寸 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.2 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 16 | 16 | 空洞和气泡面积占比 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.3 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 17 | 17 | 单个空洞尺寸 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.3 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 18 | 18 | 聚氨酯泡沫塑料密度 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.4 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 19 | 19 | 径向压缩强度或10%相对形变压缩应力 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.5 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 20 | 20 | 吸水率 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.6 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 21 | 21 | 闭孔率 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.7 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 22 | 22 | 导热系数λ50(老化前) | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.3.8 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 23 | 23 | 阀杆保温端面密封结构渗水 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.1 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 24 | 24 | 保温层受挤压径向变形量 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.2 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 25 | 25 | 外护管划痕深度 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.2 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 26 | 26 | 管端垂直度角度偏差 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.3 Technical requirements for pre-insulated directly buried valve of urban heating | ||||
| 27 | 27 | 管端焊接预留段长度 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.4 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||
| 28 | 28 | 两端预留段长度之差 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.4 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||
| 29 | 29 | 外护管外径增大率 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.5 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||
| 30 | 30 | 最大轴线偏心距 | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.6 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||
| 31 | 31 | 尺寸偏差 L | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.7 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||
| 32 | 32 | 尺寸偏差 H | 《城镇供热预制直埋保温阀门技术要求》GB/T35842-2026 5.4.7 Technical requirements for pre-insulated directly buried valve of urban heating 引用方法:GB/T 29046《城镇供热预制保温管道技术指标检测方法》 | ||||