| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑室外用格栅通用技术要求 | 1 | 相邻两竖向构件间距尺寸(固定端头) | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | |||
| 2 | 2 | 相邻两横向构件间距尺寸 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 3 | 3 | 分格对角线差 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 4 | 4 | 构件直线度 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 5 | 5 | 缝宽度设计偏差(与设计值比较) | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 6 | 6 | 同一平面高低差(与设计值比较) | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 7 | 7 | 装配间隙 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3 General technical requirements of building outdoor bar screen | ||||
| 8 | 8 | 两相邻构件之间接缝高低差 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.1 表3、7.2.2 表4 General technical requirements of building outdoor bar screen | ||||
| 9 | 9 | 竖缝直线度 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.2 表4 General technical requirements of building outdoor bar screen | ||||
| 10 | 10 | 横缝直线度 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.2 表4 General technical requirements of building outdoor bar screen | ||||
| 11 | 11 | 缝宽度(与设计值比较) | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.2.2 表4 General technical requirements of building outdoor bar screen | ||||
| 12 | 12 | 额定荷载P | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.3.2 表5 General technical requirements of building outdoor bar screen | ||||
| 13 | 13 | 额定荷载P下最大变形 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.3.2 表6 General technical requirements of building outdoor bar screen | ||||
| 14 | 14 | 额定荷载P下残余变形 | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.3.2 表6 General technical requirements of building outdoor bar screen | ||||
| 15 | 15 | 安全荷载(1.5P) | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.3.2 表6 General technical requirements of building outdoor bar screen | ||||
| 16 | 16 | 撞击能量E | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.4.2 表7 General technical requirements of building outdoor bar screen 引用方法:GB/T 21086—2007 附录F | ||||
| 17 | 17 | 降落高度H | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.4.2 表7 General technical requirements of building outdoor bar screen 引用方法:GB/T 21086—2007 附录F | ||||
| 18 | 18 | 遮阳系数SC | 《建筑室外用格栅通用技术要求》GB/T37256-2018 7.5 表8 General technical requirements of building outdoor bar screen 引用方法:JG/T 281 | ||||