| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑用单元门通用技术条件 | 1 | 门扇上、下梃与门框配合活动间隙 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.2.3 表6 General technical specification of building unit door | |||
| 2 | 2 | 关闭状态下门扇锁具侧边梃与门框配合活动间隙 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.2.3 表6 General technical specification of building unit door | ||||
| 3 | 3 | 关闭状态下门扇铰链侧边与门框间隙 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.2.3 表6 General technical specification of building unit door | ||||
| 4 | 4 | 门不同铰链轴线的同轴度 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.3.1 General technical specification of building unit door | ||||
| 5 | 5 | 闭门器固定螺丝处加强衬板厚度 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.3.2 General technical specification of building unit door | ||||
| 6 | 6 | 开锁状态锁舌突出安装表面量 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.3.3 General technical specification of building unit door | ||||
| 7 | 7 | 防破坏性能(防破坏时间) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.1 表7 General technical specification of building unit door | ||||
| 8 | 8 | 防闯入性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.2、8.4.2 General technical specification of building unit door | ||||
| 9 | 9 | 抗风压性能分级指标值p3 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.3 表8 General technical specification of building unit door | ||||
| 10 | 10 | 水密性能分级指标值Δp | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.4 表9 General technical specification of building unit door | ||||
| 11 | 11 | 气密性能分级指标值q1(单位缝长空气渗透量) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.5 表10 General technical specification of building unit door | ||||
| 12 | 12 | 气密性能分级指标值q2(单位面积空气渗透量) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.5 表10 General technical specification of building unit door | ||||
| 13 | 13 | 保温性能分级指标值K(传热系数) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.6 表11 General technical specification of building unit door | ||||
| 14 | 14 | 空气声隔声性能(Rw+Ctr) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.7 General technical specification of building unit door | ||||
| 15 | 15 | 关门噪声等效连续A声级 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.8 General technical specification of building unit door | ||||
| 16 | 16 | 关门噪声最大声级 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.8 General technical specification of building unit door | ||||
| 17 | 17 | 开启力-活动扇操作力Fh | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.9.1 表12 General technical specification of building unit door | ||||
| 18 | 18 | 开启力-锁闭装置手操作最大力Fs1 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.9.1 表12 General technical specification of building unit door | ||||
| 19 | 19 | 开启力-锁闭装置手操作最大力矩Ms1 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.9.1 表12 General technical specification of building unit door | ||||
| 20 | 20 | 开启力-锁闭装置手指操作最大力Fs2 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.9.1 表12 General technical specification of building unit door | ||||
| 21 | 21 | 开启力-锁闭装置手指操作最大力矩Ms2 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.9.1 表12 General technical specification of building unit door | ||||
| 22 | 22 | 耐软重物体撞击性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.10、8.4.10 General technical specification of building unit door | ||||
| 23 | 23 | 耐垂直荷载性能-作用荷载 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.11 General technical specification of building unit door | ||||
| 24 | 24 | 耐垂直荷载性能-门扇外边缘最大残余下沉量 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.11 General technical specification of building unit door | ||||
| 25 | 25 | 抗静扭曲性能-荷载 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.12 General technical specification of building unit door | ||||
| 26 | 26 | 抗静扭曲性能-残余位移 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.12 General technical specification of building unit door | ||||
| 27 | 27 | 对角变形性能-试验后活动扇操作力 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.13 General technical specification of building unit door | ||||
| 28 | 28 | 对角变形性能-平面内位移γ | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.13 表13 General technical specification of building unit door | ||||
| 29 | 29 | 反复启闭耐久性能-反复启闭次数 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.14 表14 General technical specification of building unit door | ||||
| 30 | 30 | 绝缘电阻(正常环境条件) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.15.1 General technical specification of building unit door | ||||
| 31 | 31 | 绝缘电阻(湿热条件) | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.15.1 General technical specification of building unit door | ||||
| 32 | 32 | 抗电强度 | 《建筑用单元门通用技术条件》GB/T38297-2019 6.4.15.2、8.4.15.2、A.3.3 General technical specification of building unit door | ||||
| 33 | 33 | 防破坏性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.1.4 General technical specification of building unit door | ||||
| 34 | 34 | 抗风压性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.3 General technical specification of building unit door 引用方法:GB/T 7106《建筑外门窗气密、水密、抗风压性能分级及检测方法》 | ||||
| 35 | 35 | 水密性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.4 General technical specification of building unit door 引用方法:GB/T 7106《建筑外门窗气密、水密、抗风压性能分级及检测方法》 | ||||
| 36 | 36 | 气密性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.5 General technical specification of building unit door 引用方法:GB/T 7106《建筑外门窗气密、水密、抗风压性能分级及检测方法》 | ||||
| 37 | 37 | 保温性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.6 General technical specification of building unit door 引用方法:GB/T 8484《建筑外门窗保温性能分级及检测方法》 | ||||
| 38 | 38 | 空气声隔声性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.7 General technical specification of building unit door 引用方法:GB/T 8485《建筑门窗空气声隔声性能分级及检测方法》 | ||||
| 39 | 39 | 关门噪声 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.8 General technical specification of building unit door | ||||
| 40 | 40 | 开启力 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.9 General technical specification of building unit door 引用方法:GB/T 9158《建筑门窗力学性能检测方法》 | ||||
| 41 | 41 | 耐垂直荷载性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.11 General technical specification of building unit door 引用方法:GB/T 29049《整樘门 垂直荷载试验》 | ||||
| 42 | 42 | 抗静扭曲性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.12 General technical specification of building unit door 引用方法:GB/T 29530《平开门和旋转门 抗静扭曲性能的测定》 | ||||
| 43 | 43 | 对角变形性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.13 General technical specification of building unit door | ||||
| 44 | 44 | 反复启闭耐久性能 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.14 General technical specification of building unit door 引用方法:GB/T 29739《门窗反复启闭耐久性试验方法》 | ||||
| 45 | 45 | 绝缘电阻 | 《建筑用单元门通用技术条件》GB/T38297-2019 8.4.15.1、A.3.2 General technical specification of building unit door | ||||
| 46 | 46 | 锁芯台肩与锁头体配合间隙 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.1.2 General technical specification of building unit door | ||||
| 47 | 47 | 吸力 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.2.1 General technical specification of building unit door | ||||
| 48 | 48 | 钥匙插拔力 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.2.2 General technical specification of building unit door | ||||
| 49 | 49 | 工作电压 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.1 General technical specification of building unit door | ||||
| 50 | 50 | 开锁灵敏度 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.4 General technical specification of building unit door | ||||
| 51 | 51 | 延时调节范围 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.4 General technical specification of building unit door | ||||
| 52 | 52 | 高温试验 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.5 表A.1 General technical specification of building unit door | ||||
| 53 | 53 | 低温试验 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.5 表A.1 General technical specification of building unit door | ||||
| 54 | 54 | 恒定湿热试验 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.3.5 表A.1 General technical specification of building unit door | ||||
| 55 | 55 | 抵抗开启拉力 | 《建筑用单元门通用技术条件》GB/T38297-2019 A.4.1 General technical specification of building unit door | ||||