| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑木框架幕墙组件 | 1 | 擦伤、划伤深度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.1.2 表1 Frame system of timber supporting curtain wall | |||
| 2 | 2 | 擦伤总面积 | 《建筑木框架幕墙组件》GB/T38704-2020 6.1.2 表1 Frame system of timber supporting curtain wall | ||||
| 3 | 3 | 划伤总长度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.1.2 表1 Frame system of timber supporting curtain wall | ||||
| 4 | 4 | 擦伤和划伤处数 | 《建筑木框架幕墙组件》GB/T38704-2020 6.1.2 表1 Frame system of timber supporting curtain wall | ||||
| 5 | 5 | 竖向构件长度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.2 表2 Frame system of timber supporting curtain wall | ||||
| 6 | 6 | 横向构件长度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.2 表2 Frame system of timber supporting curtain wall | ||||
| 7 | 7 | 截面尺寸 | 《建筑木框架幕墙组件》GB/T38704-2020 6.2 表2 Frame system of timber supporting curtain wall | ||||
| 8 | 8 | 端头斜度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.2 表2 Frame system of timber supporting curtain wall | ||||
| 9 | 9 | 槽口尺寸 | 《建筑木框架幕墙组件》GB/T38704-2020 6.2 表2 Frame system of timber supporting curtain wall | ||||
| 10 | 10 | 相邻两竖向构件间距尺寸(固定端头) | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 11 | 11 | 相邻两横向构件间距尺寸 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 12 | 12 | 分格对角线差 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 13 | 13 | 竖向构件垂直度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 14 | 14 | 相邻两横向构件的水平高差 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 15 | 15 | 横向构件水平度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 16 | 16 | 竖向构件直线度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.3 表3 Frame system of timber supporting curtain wall | ||||
| 17 | 17 | 下部立柱上端距托板距离a | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.1 Frame system of timber supporting curtain wall | ||||
| 18 | 18 | 上部立柱安装孔数量 | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.2 Frame system of timber supporting curtain wall | ||||
| 19 | 19 | 下部立柱安装孔数量 | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.2 Frame system of timber supporting curtain wall | ||||
| 20 | 20 | 孔直径d | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.2 Frame system of timber supporting curtain wall | ||||
| 21 | 21 | 孔中心距边缘尺寸b | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.3 Frame system of timber supporting curtain wall | ||||
| 22 | 22 | 孔中心间距c | 《建筑木框架幕墙组件》GB/T38704-2020 6.4.3.3 Frame system of timber supporting curtain wall | ||||
| 23 | 23 | 横梁立柱面法线挠度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.5.1.2 Frame system of timber supporting curtain wall 引用方法:GB/T 15227、附录B | ||||
| 24 | 24 | 横梁重力方向挠度 | 《建筑木框架幕墙组件》GB/T38704-2020 6.5.1.3 Frame system of timber supporting curtain wall | ||||
| 25 | 25 | 风压方向相对位移值δw | 《建筑木框架幕墙组件》GB/T38704-2020 6.5.1.3 表4 Frame system of timber supporting curtain wall | ||||
| 26 | 26 | 重力方向相对位移值δg | 《建筑木框架幕墙组件》GB/T38704-2020 6.5.1.3 表4 Frame system of timber supporting curtain wall | ||||
| 27 | 27 | 抗弯强度特征值 fmk | 《建筑木框架幕墙组件》GB/T38704-2020 表A.1、表A.2 Frame system of timber supporting curtain wall | ||||
| 28 | 28 | 抗弯弹性模量 E | 《建筑木框架幕墙组件》GB/T38704-2020 表A.1、表A.2 Frame system of timber supporting curtain wall | ||||