| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑门窗附框技术要求 | 1 | 碳酸钙掺量 | 《建筑门窗附框技术要求》GB/T39866-2021 5.6.2 a) Technical requirement of appendent frame for window and door in building | |||
| 2 | 2 | 截面宽度 | 《建筑门窗附框技术要求》GB/T39866-2021 5.6.3、5.7.2、5.8.1 Technical requirement of appendent frame for window and door in building | ||||
| 3 | 3 | 截面高度 | 《建筑门窗附框技术要求》GB/T39866-2021 5.6.3、5.7.2、5.8.1 Technical requirement of appendent frame for window and door in building | ||||
| 4 | 4 | 增强型钢壁厚 | 《建筑门窗附框技术要求》GB/T39866-2021 5.6.3 Technical requirement of appendent frame for window and door in building | ||||
| 5 | 5 | 塑料壁厚 | 《建筑门窗附框技术要求》GB/T39866-2021 5.6.3 Technical requirement of appendent frame for window and door in building | ||||
| 6 | 6 | 型材截面宽度 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 7 | 7 | 型材截面高度 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 8 | 8 | 型材加强肋厚度 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 9 | 9 | 型材壁厚 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 10 | 10 | 型材直线偏差 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 11 | 11 | 附框宽度、高度尺寸 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 12 | 12 | 附框宽度、高度尺寸对边尺寸差 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 13 | 13 | 附框对角线尺寸差 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 14 | 14 | 附框角部接缝高低差 | 《建筑门窗附框技术要求》GB/T39866-2021 表3 Technical requirement of appendent frame for window and door in building | ||||
| 15 | 15 | 抗拉强度 | 《建筑门窗附框技术要求》GB/T39866-2021 表4、表5 Technical requirement of appendent frame for window and door in building | ||||
| 16 | 16 | 防腐层厚度 | 《建筑门窗附框技术要求》GB/T39866-2021 表4 Technical requirement of appendent frame for window and door in building | ||||
| 17 | 17 | 耐盐酸性 | 《建筑门窗附框技术要求》GB/T39866-2021 表4、表5 Technical requirement of appendent frame for window and door in building | ||||
| 18 | 18 | 耐碱性 | 《建筑门窗附框技术要求》GB/T39866-2021 表4、表5、表6 Technical requirement of appendent frame for window and door in building | ||||
| 19 | 19 | 耐盐雾腐蚀性(AASS 1000 h) | 《建筑门窗附框技术要求》GB/T39866-2021 表4、表5 Technical requirement of appendent frame for window and door in building | ||||
| 20 | 20 | 密度 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 21 | 21 | 吸水率(24h) | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 22 | 22 | 吸水厚度膨胀率(72h) | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 23 | 23 | 硬度 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 24 | 24 | 强度 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 25 | 25 | 弯曲弹性模量 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 26 | 26 | 高低温反复尺寸变化率 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 27 | 27 | 低温落锤冲击 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 28 | 28 | 型材握螺钉力 | 《建筑门窗附框技术要求》GB/T39866-2021 表6、表7、表8 Technical requirement of appendent frame for window and door in building | ||||
| 29 | 29 | 耐候性(6000h)静曲强度保留率 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 30 | 30 | 耐酸性 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 31 | 31 | 甲醛释放量 | 《建筑门窗附框技术要求》GB/T39866-2021 表6 Technical requirement of appendent frame for window and door in building | ||||
| 32 | 32 | 防腐剂透入度 | 《建筑门窗附框技术要求》GB/T39866-2021 表7 Technical requirement of appendent frame for window and door in building | ||||
| 33 | 33 | 载药量 | 《建筑门窗附框技术要求》GB/T39866-2021 表7 Technical requirement of appendent frame for window and door in building | ||||
| 34 | 34 | 表观密度 | 《建筑门窗附框技术要求》GB/T39866-2021 表8 Technical requirement of appendent frame for window and door in building | ||||
| 35 | 35 | 压缩变形强度(压缩比为10%) | 《建筑门窗附框技术要求》GB/T39866-2021 表8 Technical requirement of appendent frame for window and door in building | ||||
| 36 | 36 | 宽度、高度构造尺寸允许偏差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.1 表A.1 Technical requirement of appendent frame for window and door in building | ||||
| 37 | 37 | 宽度、高度对边尺寸差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.1 表A.1 Technical requirement of appendent frame for window and door in building | ||||
| 38 | 38 | 对角线尺寸差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.1 表A.1、A.2.3 表A.3 Technical requirement of appendent frame for window and door in building | ||||
| 39 | 39 | 垂直方向洞口位置允许偏差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.1 表A.1 Technical requirement of appendent frame for window and door in building | ||||
| 40 | 40 | 水平方向洞口位置允许偏差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.1 表A.1 Technical requirement of appendent frame for window and door in building | ||||
| 41 | 41 | 洞口与附框的间隙 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.1.2 表A.2 Technical requirement of appendent frame for window and door in building | ||||
| 42 | 42 | 附框宽度、高度构造尺寸允许偏差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.3 表A.3 Technical requirement of appendent frame for window and door in building | ||||
| 43 | 43 | 附框宽度、高度构造尺寸对边尺寸差 | 《建筑门窗附框技术要求》GB/T39866-2021 A.2.3 表A.3 Technical requirement of appendent frame for window and door in building | ||||