| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 建筑用通风百叶窗通风及防雨性能 | 1 | 压差测量精度 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.6 表3 Test method of ventilation and rain resistance performance for ventilation louvers of building | ||
| 2 | 2 | 风速测量误差 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.7 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 3 | 3 | 空气流量计允许误差 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.8 表4 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 4 | 4 | 温度测量精度 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.9 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 5 | 5 | 计时器精度 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.10 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 6 | 6 | 雨量计误差 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.11 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 7 | 7 | 系统控制允许误差 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.12 表5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 8 | 8 | 喷嘴喷淋角度 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 9 | 9 | 喷淋量 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 10 | 10 | 喷淋间隔 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 11 | 11 | 校准板单位开孔面积透水量 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 12 | 12 | 雨量计采集水量偏差 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 13 | 13 | 透过校准板透水量占比 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.5 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 14 | 14 | 平面Y单点流速 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.2 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 15 | 15 | 稳流网通风面积 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.2 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 16 | 16 | 稳流网间距 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.2 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 17 | 17 | 环境箱尺寸 | 051403 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.3 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 18 | 18 | 雨水收集箱尺寸 | 051403 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 6.2.4 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 19 | 19 | 试件外框尺寸 | 051403 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 7.1 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 20 | 20 | 实验室环境温度 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 8.1/9.1.1/10.1.1 Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 21 | 21 | 滴水管淋水量 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 9.2 a) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 22 | 22 | 滴水岐管淋水量 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 9.2 a) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 23 | 23 | 静态防雨最小测定点透水率 | 051412 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 9.2 c) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 24 | 24 | 静态防雨最大测定点透水率 | 051412 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 9.2 c) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 25 | 25 | 静态防雨最大测定点流速 | 051412 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 9.2 c) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 26 | 26 | 校准板透水流量 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 10.2.1.1 b) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 27 | 27 | 外部加压风速 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 10.2.1.1 a) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||
| 28 | 28 | 核心区流速范围 | 051499 | 《建筑用通风百叶窗通风及防雨性能 检测方法》GB/T39969-2021 10.2.1.1 e) Test method of ventilation and rain resistance performance for ventilation louvers of building | |||