| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 变电站二次系统 | 1 | 环境温度范围 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 表1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | ||
| 2 | 2 | 环境温度最大变化率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 表1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 3 | 3 | 相对湿度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 表1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 4 | 4 | 最大绝对湿度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 表1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 5 | 5 | 大气压力(海拔不超过1000m) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 6 | 6 | 大气压力(海拔不超过3000m) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 7 | 7 | 水平加速度(抗震动能力) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.1.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 8 | 8 | 垂直加速度(抗震动能力) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.1.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 9 | 9 | 贮存环境温度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 10 | 10 | 贮存相对湿度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 11 | 11 | 运输环境温度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 12 | 12 | 运输相对湿度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 5.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 13 | 13 | 电压测量误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 14 | 14 | 电流测量误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 15 | 15 | 有功、无功测量误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 16 | 16 | 频率测量误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 17 | 17 | 直流量采集误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 18 | 18 | SOE分辨率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 19 | 19 | 遥控动作正确率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 20 | 20 | 对时误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.1.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 21 | 21 | 间隔层设备到管理单元的事件报告传输时间 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 6.2.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 22 | 22 | 管理单元日志条目数 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 6.2.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 23 | 23 | 二次设备运维管理主站接入数 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 6.2.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 24 | 24 | CPU平均负荷率(正常运行) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 25 | 25 | CPU平均负荷率(电力系统故障雪崩) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 26 | 26 | 站控层网络通信状态变化反应时间 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 27 | 27 | 单网口同时建立主站通信链接数(DL/T634.5104) | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 28 | 28 | 同时建立客户端连接数(GB/T45906.3) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 29 | 29 | 每主站缓存SOE条数(DL/T634.5104) | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.6 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 30 | 30 | 24h守时误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.7 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 31 | 31 | 整机功耗 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.8 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 32 | 32 | 千/百兆自适应网口数量 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.2.3.9 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 33 | 33 | 交换机吞吐量 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 34 | 34 | 交换机端口转发速率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 35 | 35 | 交换机平均转发延时 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 36 | 36 | 时延抖动最大值 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 37 | 37 | 帧丢失率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 38 | 38 | 不堵塞端口的帧丢失率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.6 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 39 | 39 | SNTP对时的时间同步准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.3.3.7 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 40 | 40 | 脉冲信号准时沿上升时间 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 41 | 41 | 脉冲信号上升沿的时间准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 42 | 42 | IRIG-B(DC)码上升沿的时间准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 43 | 43 | IRIG-B码抖动时间 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 44 | 44 | 串行口时间报文对时准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 45 | 45 | NTP/SNTP网络对时报文对时准确度 | 041803 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 46 | 46 | 守时12h状态下的时间准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.4.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 47 | 47 | 测量准确度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements 引用方法:DL/T280 | |||
| 48 | 48 | 连续录波记录采样率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 49 | 49 | 连续录波记录保存时间 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 50 | 50 | 低频振荡频率监视范围 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 51 | 51 | 次/超同步振荡频率监视范围 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 52 | 52 | 动态数据时标与数据输出时刻的时间差 | 041804 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.5 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 53 | 53 | 装置对时误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.6 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 54 | 54 | 失去同步时钟信号60min以内相位测量误差改变量 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.5.3.6 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 55 | 55 | 转发实时动态数据的延迟时间 | 041804 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.1a Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 56 | 56 | 能接入的主站个数 | 041802 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.1b Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 57 | 57 | 能接入的PMU装置台数 | 041802 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.1c Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 58 | 58 | 可接入的间隔数 | 041802 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.1c Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 59 | 59 | 通信端口个数 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.1d Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 60 | 60 | 动态数据最高记录速率 | 041804 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.2a Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 61 | 61 | 动态数据保存时间 | 041804 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 7.6.3.2b Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 62 | 62 | 电能质量设备准确度 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 8.3.2.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements 引用方法:GB/T19862 | |||
| 63 | 63 | 用于直连的端口采样值发送间隔离散值 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.1.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 64 | 64 | 采样值总延时 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 65 | 65 | 带级联功能的采样响应延时 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.1.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 66 | 66 | 对时精度 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.1.4、9.3.2.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 67 | 67 | 失去同步时钟信号10min以内的守时误差 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.1.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 68 | 68 | 跳闸、合闸继电器接点出口动作时间 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.2.1 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 69 | 69 | 开入变位到GOOSE信号发出时间延时 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.2.2 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 70 | 70 | 事件分辨率 | 041899 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 9.3.2.3 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||
| 71 | 71 | 电力波分复用设备单机传输时延 | 041801 | 《变电站二次系统 第5部分:保护控制及相关设备》GB/T45906.5-2025 10.3.4 Substation secondary system—Part 5: Protection and control system with their equipment's requirements | |||