| 序号 | 检测对象 | 项目/参数 | 领域代码 | 检测标准(方法)名称及编号(含年号) | 说明 | 备注 | |
|---|---|---|---|---|---|---|---|
| 序号 | 名称 | ||||||
| 1 | 印制电路用覆铜箔酚醛纸层压板 | 1 | 凹痕总点值 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.1.2 Phenolic celluloss paper copper clad laminated sheets for printed circuit | |||
| 2 | 2 | 针孔总数(最大直径0.10mm~0.38mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.1.2 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 3 | 3 | 针孔最大直径 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.1.2 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 4 | 4 | 标称板面尺寸偏差 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.1 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 5 | 5 | 剪切板尺寸允许偏差 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.2 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 6 | 6 | 垂直度 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.3 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722—2017《印制电路用刚性覆铜箔层压板试验方法》 | ||||
| 7 | 7 | 厚度偏差(标称厚度0.5mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 8 | 8 | 厚度偏差(标称厚度0.6mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 9 | 9 | 厚度偏差(标称厚度0.8mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 10 | 10 | 厚度偏差(标称厚度1.0mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 11 | 11 | 厚度偏差(标称厚度1.2mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 12 | 12 | 厚度偏差(标称厚度1.5mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 13 | 13 | 厚度偏差(标称厚度1.6mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 14 | 14 | 厚度偏差(标称厚度2.0mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 15 | 15 | 厚度偏差(标称厚度2.4mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 16 | 16 | 厚度偏差(标称厚度3.2mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.2.4 Phenolic celluloss paper copper clad laminated sheets for printed circuit | ||||
| 17 | 17 | 弓曲和扭曲(0.50≤t<0.80mm,试样尺寸≤200mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.3 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722—2017中5.4 | ||||
| 18 | 18 | 弓曲和扭曲(0.50≤t<0.80mm,试样尺寸200~300mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.3 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722—2017中5.4 | ||||
| 19 | 19 | 弓曲和扭曲(t≥0.80mm,试样尺寸≤200mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.3 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722—2017中5.4 | ||||
| 20 | 20 | 弓曲和扭曲(t≥0.80mm,试样尺寸200~300mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.3 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722—2017中5.4 | ||||
| 21 | 21 | 剥离强度(验收态) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.2.1 | ||||
| 22 | 22 | 剥离强度(10 s热应力后,260°C浮焊法) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.2.2 | ||||
| 23 | 23 | 体积电阻率(恒定湿热处理恢复后) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.3 | ||||
| 24 | 24 | 表面电阻率(恒定湿热处理恢复后) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.3 | ||||
| 25 | 25 | 绝缘电阻(验收态) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.4 | ||||
| 26 | 26 | 绝缘电阻(水煮后) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.4 | ||||
| 27 | 27 | 吸水率(厚度0.5 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 28 | 28 | 吸水率(厚度0.6 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 29 | 29 | 吸水率(厚度0.8 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 30 | 30 | 吸水率(厚度1.0 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 31 | 31 | 吸水率(厚度1.2 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 32 | 32 | 吸水率(厚度1.5 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 33 | 33 | 吸水率(厚度1.6 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 34 | 34 | 吸水率(厚度2.0 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 35 | 35 | 吸水率(厚度2.4 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 36 | 36 | 吸水率(厚度3.2 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 9.2 | ||||
| 37 | 37 | 击穿电压 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.1 | ||||
| 38 | 38 | 介电常数(1 MHz) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.5 | ||||
| 39 | 39 | 介质损耗角正切值(1 MHz) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.5 | ||||
| 40 | 40 | 弯曲强度(纵向,适用于厚度≥0.8 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.3 | ||||
| 41 | 41 | 弯曲强度(横向,适用于厚度≥0.8 mm) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.3 | ||||
| 42 | 42 | 耐电弧性 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.6 | ||||
| 43 | 43 | 热应力(未蚀刻,浮焊法)条件A 260°C,10s | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.5 | ||||
| 44 | 44 | 热应力(未蚀刻,浮焊法)条件B 270°C,10s | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.5 | ||||
| 45 | 45 | 热应力(未蚀刻,浮焊法)条件C 270°C,20s | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.5 | ||||
| 46 | 46 | 拉脱强度 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.1 | ||||
| 47 | 47 | 燃烧性(垂直法) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.4.1 | ||||
| 48 | 48 | 燃烧性(水平法) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.4.2 | ||||
| 49 | 49 | 相比漏电起痕指数(CTI)最小值 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 8.7 | ||||
| 50 | 50 | 耐热性(130°C) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.12 | ||||
| 51 | 51 | 耐热性(190°C) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.12 | ||||
| 52 | 52 | 耐化学性(耐氢氧化钠) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.2 | ||||
| 53 | 53 | 耐化学性(耐其他药品) | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 6.2 | ||||
| 54 | 54 | 冲孔性 | 《印制电路用覆铜箔酚醛纸层压板》GB/T4723-2017 5.4 表7 Phenolic celluloss paper copper clad laminated sheets for printed circuit 引用方法:GB/T 4722-2017 7.5 | ||||