项目
限值 / 检出限 / 定量限
单位
出处
d(管径)
无引出帽八脚收讯放大管≤ 29 mm (d=29_{-2}^{0},上限0)
≥ 27 mm (d=29_{-2}^{0},下限-2)
≤ 39 mm (d=39_{-2}^{0},上限0)
≥ 37 mm (d=39_{-2}^{0},下限-2)mm4.1.3.1 表4
h_max
无引出帽八脚收讯放大管≤ 56 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 61 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 66 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 71 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 76 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 81 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 86 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 91 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 91 mm (d=39,J8-1/J8-1B/J8-1G)
≤ 96 mm (d=39,J8-1/J8-1B/J8-1G)
≤ 106 mm (d=39,J8-1/J8-1B/J8-1G)mm4.1.3.1 表4
h_1max
无引出帽八脚收讯放大管≤ 70 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 75 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 80 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 85 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 90 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 95 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 100 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 105 mm (d=29,J8-1/J8-1B/J8-1D)
≤ 105 mm (d=39,J8-1/J8-1B/J8-1G)
≤ 110 mm (d=39,J8-1/J8-1B/J8-1G)
≤ 120 mm (d=39,J8-1/J8-1B/J8-1G)mm4.1.3.1 表4
d(管径)
有引出帽八脚收讯放大管≤ 29 mm (d=29_{-2}^{0},上限0)
≥ 27 mm (d=29_{-2}^{0},下限-2)
≤ 39 mm (d=39_{-2}^{0},上限0)
≥ 37 mm (d=39_{-2}^{0},下限-2)mm4.1.3.2 表5
h_max
有引出帽八脚收讯放大管≤ 81 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 91 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 101 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 85 mm (d=39,J8-1/J8-1G,MY9)
≤ 94 mm (d=39,J8-1/J8-1G,MY9)
≤ 104 mm (d=39,J8-1/J8-1G,MY9)
≤ 113 mm (d=39,J8-1/J8-1G,MY9)mm4.1.3.2 表5
h_1max
有引出帽八脚收讯放大管≤ 95 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 105 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 115 mm (d=29,J8-1/J8-1B/J8-1D,MY6.5/MY9)
≤ 99 mm (d=39,J8-1/J8-1G,MY9)
≤ 108 mm (d=39,J8-1/J8-1G,MY9)
≤ 118 mm (d=39,J8-1/J8-1G,MY9)
≤ 127 mm (d=39,J8-1/J8-1G,MY9)mm4.1.3.2 表5
d(管径)
大九脚收讯放大管≤ 30 mm (d=30_{-2}^{0},上限0)
≥ 28 mm (d=30_{-2}^{0},下限-2)mm4.1.4.1 表6
h
大九脚收讯放大管≥ 80 mm (h=80±3,下限77)
≤ 83 mm (h=80±3,上限83)mm4.1.4.1 表6
h_1max
大九脚收讯放大管≤ 94 mm (J9-2/J9-2A,MY6.5)mm4.1.4.1 表6
h_2max
大九脚收讯放大管≤ 102.5 mm (J9-2/J9-2A,MY6.5)mm4.1.4.1 表6
管壳轴线与管基轴线偏离
大九脚收讯放大管≤ 5 ° (大九脚收讯放大管)°4.1.4.2
d(管径)
十三脚收讯放大管≤ 30 mm (d=30_{-2}^{0},上限0)
≥ 28 mm (d=30_{-2}^{0},下限-2)mm4.1.5.1 表7
h
十三脚收讯放大管≥ 24.5 mm (h=26±1.5,下限24.5)
≤ 27.5 mm (h=26±1.5,上限27.5)mm4.1.5.1 表7
h_1max
十三脚收讯放大管≤ 34.5 mm (J13-1/J13-1A)mm4.1.5.1 表7
管壳轴线与管基轴线偏离
十三脚收讯放大管≤ 5 ° (十三脚收讯放大管)°4.1.5.2
l(长度)
矩形收讯放大管≤ 28 mm (l=28_{-2}^{0},上限0)
≥ 26 mm (l=28_{-2}^{0},下限-2)mm4.1.6.1 表8
b(宽度)
矩形收讯放大管≤ 22 mm (b=22_{-2}^{0},上限0)
≥ 20 mm (b=22_{-2}^{0},下限-2)mm4.1.6.1 表8
h
矩形收讯放大管≥ 24.5 mm (h=26±1.5,下限24.5)
≤ 27.5 mm (h=26±1.5,上限27.5)
≥ 43.5 mm (h=45±1.5,下限43.5)
≤ 46.5 mm (h=45±1.5,上限46.5)mm4.1.6.1 表8
h_1max
矩形收讯放大管≤ 34.5 mm (h=26±1.5,J11-1)
≤ 53.5 mm (h=45±1.5,J11-1)mm4.1.6.1 表8
管壳轴线与管基轴线偏离
矩形收讯放大管≤ 5 ° (矩形收讯放大管)°4.1.6.2
d(MY类引出帽连接直径)
MY类引出帽≤ 4.8 mm (MY4.8,上限0)
≥ 4.61 mm (MY4.8,下限-0.19)
≤ 6.5 mm (MY6.5,上限0)
≥ 6.31 mm (MY6.5,下限-0.19)
≤ 9 mm (MY9,上限0)
≥ 8.81 mm (MY9,下限-0.19)
≤ 14.5 mm (MY14.5,上限0)
≥ 14.21 mm (MY14.5,下限-0.29)
≤ 20.5 mm (MY20,上限0)
≥ 20.21 mm (MY20,下限-0.29)mm4.2.3 表9
h_min
MY类引出帽≥ 3 mm (MY4.8)
≥ 5 mm (MY6.5)
≥ 7.5 mm (MY9)
≥ 10 mm (MY14.5)
≥ 20 mm (MY20)mm4.2.3 表9
h_1
MY类引出帽≤ 4.8 mm (MY4.8,不含焊料,允许随焊料增加0.5)
≤ 7 mm (MY6.5,不含焊料,允许随焊料增加0.5)
≤ 10 mm (MY9,不含焊料,允许随焊料增加0.5)
≤ 13 mm (MY14.5,不含焊料,允许随焊料增加1)
≤ 25.5 mm (MY20,不含焊料,允许随焊料增加1.5)mm4.2.3 表9
d(MP类引出帽连接直径)
MP类引出帽≤ 8.19 mm (MP8A,上限+0.19)
≥ 8 mm (MP8A,下限0)
≤ 8.19 mm (MP8B,上限+0.19)
≥ 8 mm (MP8B,下限0)
≤ 8.19 mm (MP8C,上限+0.19)
≥ 8 mm (MP8C,下限0)mm4.2.4 表10
d_1max
MP类引出帽≤ 14.5 mm (MP8A)
≤ 14.5 mm (MP8B)
≤ 14.5 mm (MP8C)mm4.2.4 表10
h_min
MP类引出帽≥ 4.2 mm (MP8A)
≥ 3.5 mm (MP8B)
≥ 3.5 mm (MP8C)mm4.2.4 表10
h_1min
MP类引出帽≥ 6 mm (MP8A)
≥ 5 mm (MP8B)
≥ 5 mm (MP8C)mm4.2.4 表10
插入和拔出管帽时向引出帽帽缘平面垂直方向施加的总压力
收讯放大管引出帽≤ 3.6 kg (插入和拔出管帽时)kg4.2.5
引出帽帽缘平面与引出帽中心处正处于玻璃原始外形平面之间的夹角