项目
限值 / 检出限 / 定量限
单位
出处
驻波比
7.1 · 同轴电缆馈线系统≤ 1.15 (频段1.427~1.535GHz、1.700~1.900GHz、1.900~2.300GHz、2.300~2.500GHz,A级)
≤ 1.2 (频段1.427~1.535GHz、1.700~1.900GHz、1.900~2.300GHz、2.300~2.500GHz,B级)
≤ 1.25 (频段1.427~1.535GHz、1.700~1.900GHz、1.900~2.300GHz、2.300~2.500GHz,C级)
≤ 1.25 (频段2.500~2.700GHz,A级)
≤ 1.3 (频段2.500~2.700GHz,B级)
≤ 1.35 (频段2.500~2.700GHz,C级)6.1 表1
插入衰耗(中心频率)
7.2 · 同轴电缆馈线系统≤ (频段1.427~1.535GHz,I级:2+0.03L(L为实际馈线长度,m))
≤ (频段1.427~1.535GHz,II级:2+0.035L)
≤ (频段1.427~1.535GHz,III级:2+0.052L)
≤ (频段1.427~1.535GHz,IV级:2+0.055L)
≤ (频段1.700~1.900GHz,I级:2+0.034L)
≤ (频段1.700~1.900GHz,II级:2+0.039L)
≤ (频段1.700~1.900GHz,III级:2+0.060L)
≤ (频段1.700~1.900GHz,IV级:2+0.065L)
≤ (频段1.900~2.300GHz,I级:2+0.037L)
≤ (频段1.900~2.300GHz,II级:2+0.043L)
≤ (频段1.900~2.300GHz,III级:2+0.065L)
≤ (频段1.900~2.300GHz,IV级:2+0.070L)
≤ (频段2.300~2.500GHz,I级:2+0.040L)
≤ (频段2.300~2.500GHz,II级:2+0.046L)
≤ (频段2.300~2.500GHz,III级:2+0.070L)
≤ (频段2.300~2.500GHz,IV级:2+0.075L)
≤ (频段2.500~2.700GHz,I级:2+0.042L)
≤ (频段2.500~2.700GHz,II级:2+0.050L)
≤ (频段2.500~2.700GHz,III级:2+0.075L)
≤ (频段2.500~2.700GHz,IV级:2+0.080L)dB6.1 表1
驻波比
7.1 · 椭圆软波导馈线系统≤ 1.15 (频段2.500~2.700GHz,A级)
≤ 1.2 (频段2.500~2.700GHz,B级)
≤ 1.25 (频段2.500~2.700GHz,C级)
≤ 1.1 (频段3.400~3.800GHz、3.600~4.200GHz、3.800~4.200GHz、4.400~5.000GHz、5.925~6.425GHz、6.425~7.125GHz、7.125~7.725GHz、7.725~8.275GHz、8.200~8.500GHz、8.500~8.750GHz、10.700~11.700GHz、12.750~13.250GHz、14.40~15.35GHz,A级)
≤ 1.15 (频段3.400~3.800GHz、3.600~4.200GHz、3.800~4.200GHz、4.400~5.000GHz、5.925~6.425GHz、6.425~7.125GHz、7.125~7.725GHz、7.725~8.275GHz、8.200~8.500GHz、8.500~8.750GHz、10.700~11.700GHz、12.750~13.250GHz、14.40~15.35GHz,B级)
≤ 1.2 (频段3.400~3.800GHz、3.600~4.200GHz、3.800~4.200GHz、4.400~5.000GHz、5.925~6.425GHz、6.425~7.125GHz、7.125~7.725GHz、7.725~8.275GHz、8.200~8.500GHz、8.500~8.750GHz、10.700~11.700GHz、12.750~13.250GHz、14.40~15.35GHz,C级)6.1 表2
插入衰耗(中心频率)
7.2 · 椭圆软波导馈线系统≤ (频段2.500~2.700GHz:1.0+0.020L(L为实际馈线长度,m))
≤ (频段3.400~3.800GHz:1.0+0.030L)
≤ (频段3.600~4.200GHz:1.0+0.030L)
≤ (频段3.800~4.200GHz:1.0+0.030L)
≤ (频段4.400~5.000GHz:1.0+0.035L)
≤ (频段5.925~6.425GHz:1.2+0.040L)
≤ (频段6.425~7.125GHz:1.2+0.050L)
≤ (频段7.125~7.725GHz:1.2+0.055L)
≤ (频段7.725~8.275GHz:1.2+0.063L)
≤ (频段8.200~8.500GHz:1.2+0.070L)
≤ (频段8.500~8.750GHz:1.2+0.070L)
≤ (频段10.700~11.700GHz:1.5+0.095L)
≤ (频段12.750~13.250GHz:1.5+0.120L)
≤ (频段14.40~15.35GHz:1.5+0.145L)dB6.1 表2
气密性能(内部气压)
7.3 · 充气馈线系统≥ 10 kPa (初始内部气压30kPa,24h后)kPa6.3
一次性最小弯曲半径
同轴电缆≤ 600 mm (一次性弯曲,弯曲后应满足电气指标要求)mm6.4.1
一次性最小弯曲半径(E面)
椭圆软波导馈线系统≤ 800 mm (频段2.500~2.700GHz)
≤ 500 mm (频段3.400~4.200GHz)
≤ 400 mm (频段4.400~5.000GHz)
≤ 400 mm (频段5.925~6.425GHz)
≤ 300 mm (频段6.425~7.125GHz)
≤ 300 mm (频段7.125~7.725GHz)
≤ 300 mm (频段7.725~8.275GHz)
≤ 300 mm (频段8.200~8.750GHz)
≤ 200 mm (频段10.700~11.700GHz)
≤ 150 mm (频段12.750~13.250GHz)
≤ 150 mm (频段14.400~15.350GHz)mm6.4.2 表3
一次性最小弯曲半径(H面)
椭圆软波导馈线系统≤ 2000 mm (频段2.500~2.700GHz)
≤ 1000 mm (频段3.400~4.200GHz)
≤ 800 mm (频段4.400~5.000GHz)
≤ 800 mm (频段5.925~6.425GHz)
≤ 800 mm (频段6.425~7.125GHz)
≤ 600 mm (频段7.125~7.725GHz)
≤ 600 mm (频段7.725~8.275GHz)
≤ 600 mm (频段8.200~8.750GHz)
≤ 350 mm (频段10.700~11.700GHz)
≤ 300 mm (频段12.750~13.250GHz)
≤ 300 mm (频段14.400~15.350GHz)mm6.4.2 表3
扭角度
椭圆软波导馈线系统≤ 1.0 °/m (频段2.500~2.700GHz)
≤ 1.5 °/m (频段3.400~4.200GHz)
≤ 1.5 °/m (频段4.400~5.000GHz)
≤ 3.0 °/m (频段5.925~6.425GHz)
≤ 3.0 °/m (频段6.425~7.125GHz)
≤ 3.0 °/m (频段7.125~7.725GHz)
≤ 3.0 °/m (频段7.725~8.275GHz)
≤ 3.0 °/m (频段8.200~8.750GHz)
≤ 6.0 °/m (频段10.700~11.700GHz)
≤ 6.0 °/m (频段12.750~13.250GHz)
≤ 6.0 °/m (频段14.400~15.350GHz)°/m6.4.2 表3
最大弯曲角度(E面)
矩形软波导(长度300mm)≤ 25 ° (表3所列全部频段)°6.4.2 表3
最大弯曲角度(H面)
矩形软波导(长度300mm)≤ 15 ° (表3所列全部频段)°6.4.2 表3
最大扭转角度
可扭转矩形软波导≤ 15 ° (表3所列全部频段)°6.4.2 表3
驻波比
A3.1(与7.1相同) · 圆形波导馈线系统(总长50m,含圆形波导及器件40m、矩形波导及其器件10m)≤ 1.1 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级A)
≤ 1.15 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级B)
≤ 1.2 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级C)无量纲A2.1 表A1
插入衰耗(中心频率)
A3.2(与7.2相同) · 圆形波导馈线系统(总长50m,含圆形波导及器件40m、矩形波导及其器件10m)≤ 2 dB (频段3.4~3.8GHz、3.8~4.2GHz;中心频率)dBA2.1 表A1
正交极化隔离度
A3.3 · 圆形波导馈线系统(总长50m,含圆形波导及器件40m、矩形波导及其器件10m)≥ 30 dB (频段3.4~3.8GHz、3.8~4.2GHz;等级A)
≥ 30 dB (频段3.4~3.8GHz、3.8~4.2GHz;等级B)
≥ 27 dB (频段3.4~3.8GHz、3.8~4.2GHz;等级C)dBA2.1 表A1
环境温度
圆形波导馈线系统≥ -45 ℃ (下限)
≤ 55 ℃ (上限)℃A2.2
气密性能(24h后内部气压)
A3.4(与7.3相同) · 充气圆形馈线系统≥ 10 kPa (初始内部气压30kPa,24h后)kPaA2.3
圆形软波导最大弯曲角度
圆形馈线系统≤ 4 ° (频段3.4~3.8GHz、3.8~4.2GHz)°A2.4 表A2
矩形软波导最大弯曲角度(E面)
圆形馈线系统≤ 30 ° (频段3.4~3.8GHz、3.8~4.2GHz;E面)°A2.4 表A2
矩形软波导最大弯曲角度(H面)
圆形馈线系统≤ 15 ° (频段3.4~3.8GHz、3.8~4.2GHz;H面)°A2.4 表A2
矩形软波导最大扭转角度
圆形馈线系统≤ 15 ° (频段3.4~3.8GHz、3.8~4.2GHz)°A2.4 表A2
驻波比
B3.1(与7.1相同) · 矩形波导馈线系统(总长30m,矩形弯头总数不超过5个)≤ 1.1 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级A)
≤ 1.15 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级B)
≤ 1.2 无量纲 (频段3.4~3.8GHz、3.8~4.2GHz;等级C)无量纲B2.1 表B1
插入衰耗(中心频率)
B3.2(与7.2相同) · 矩形波导馈线系统(总长30m,矩形弯头总数不超过5个)≤ 2 dB (频段3.4~3.8GHz、3.8~4.2GHz;中心频率)dBB2.1 表B1
正交极化隔离度
B3.3(与A3.3相同) · 矩形波导馈线系统(总长30m,矩形弯头总数不超过5个)≥ 30 dB (频段3.4~3.8GHz、3.8~4.2GHz)dBB2.1 表B1
环境温度
矩形波导馈线系统≥ -45 ℃ (下限)
≤ 55 ℃ (上限)℃B2.2
气密性能(24h后内部气压)
B3.4 · 充气矩形波导馈线系统≥ 10 kPa (初始内部气压30kPa,24h后)kPaB2.3
矩形软波导最大弯曲角度(E面)
矩形波导馈线系统≤ 30 ° (频段3.4~3.8GHz、3.8~4.2GHz;E面)°B2.4 表B2
矩形软波导最大弯曲角度(H面)
矩形波导馈线系统≤ 15 ° (频段3.4~3.8GHz、3.8~4.2GHz;H面)°B2.4 表B2
矩形软波导最大扭转角度
矩形波导馈线系统≤ 15 ° (频段3.4~3.8GHz、3.8~4.2GHz)°B2.4 表B2